Screwfix electric hob. ★★★★★ Read 9 reviews. Screwfix electric hob

 
 ★★★★★ Read 9 reviewsScrewfix electric hob  I read the instruction manual and it said for 240v connections to put the brown/black wires together on the live circuit, earth for earth and the blue/grey wires on the neutral

Unlike gas hobs, there are several types of electric hob, and choosing the right one for you can be confusing. K Piezoelectric Gas Lighter. Now we take off the first 10 amps and then use 30% of the remainder so, 33. It's rated at 32 amp, recently got my entire fuse box re-done a few months back due to problems with it and I've no idea if this is supported. My question is, what is an omnipolar cut. If you must go the FCU route then just go on the Screwfix site and type FCU in the search box. (62) From £349. Includes baking tray, trivet and shelf. 04 amps. Sparkielev said: ↑. 2 x Plate Sizes. 00. There are many different ways, 3 circuits has its benefits if you have room in cu. It can move around slightly and I'm worried that with it not being secure it might affect the. 320-320B Vauxhall Bridge Road. The hob can run on 6mm and even 2. an electric hob and a built in electric oven (Smeg) in a domestic kitchen. I edited my reply and agree. T+E cable, what a want to know is can both new Bosch appliances be hard wired to a ( cooker ) twin junction box by. 5mm2 ring which is protected by a 32A MCB. com. oven and hob are both electric hob has electric plates. 1KW/32amp. 30007. 5mm cable, but you need to change some jump connections on the unit itself depending on the power source; But it will not work at full capacity which defeats the. Coloumb Screwfix Select. Unfortunately there are no regs for electric hobs of any type. 4. Apart from this risk of the entire hob detaching and dropping into the cupboard below, (potentially tipping a pan of boiling water down your lower body causing life changing injuries) moisture could be making its way into the electrical components of your hob causing. (6mm2 T&E feed to switched spur, 2. Buy Light Bulbs at Screwfix. Home Tags > hob. com. Bob Rathbone Screwfix Select. £438. Buy any 10+ Save 10% - View Offer. It's a new build, only 4 years old and has been fine. To do this drill a small hole just big enough for the flex in the back of the side panel, feed the flex through, fit a plug. The rail should in theory not encroach into the aperture cut Into the worktop to accommodate the hob. This is why 3kW immersion heaters are on separate circuits. Repair Service Contact. But the hob draws 7. Agreed UP, 10mm for a standard domestic cooker circuit is a total waste of money (and copper!) seneca, Feb 28, 2017. No Timer Function. Bostik FP401 Fire Resistant Acrylic Sealant White 310ml (572JE) compare. What is the standard way? Is it just a 6/10mm radial fed by a 32a MCB/RCBO, then onto a 45a DP switch above worktop, then onto a dual 45a plate outlet, then 2 feeds one to hob other to cooker?. Page 2 of 2 < Prev 1 2. Hello, got a new induction hob to replace an old electric hob (the old style with raised heat elements that take an hour to heat up then 3 hrs to cool down) it is all plumbed in with a big red switch and theres a junction box behind the cooker for easy change over, just wanted to know is it just a case of connecting the right wires up and. Option A i thought would be to remove the 2Gang cooker switch with switched 13amp single socket outlet, and change to a single cooker switch first and then connect a dual outlet plate, then connect the oven and 2 zone hob to the Dual outlet plate. Flat surface is easy to clean. Free next day delivery available. Screwfix: Thousands of products at trade prices | FREE delivery available 7 days a week | FREE click & collect in as little as a minute | Hundreds of storesHi mate thanks for reply im trying to avoid anymore cost if i dont have to, this house has already cost me enough lol, im guessing the pipe is ok but if your saying it 100% needs a gas safe engineer to cap it then i will get it done, but if your not sure then im trying to get a gas safe engineer to tell me if it needs it or not before i fit the electric hob, hope. 590 mm. oven would go on a fused spur, the hob definantly would not, the hood should be a seperate consideration (on the kitchen ring etc). Buy Fires, Stoves & Electric Heating at Screwfix. On this panel is a number of diagrams showing the wiring config. Screwfix Community Forum. 19 Inc Vat. 3/5. I haven't decided 100% on a hob yet, but the power supplies required from the ones I am looking at are. 2kW) - ie 1. The pan base heats up. Typically used for supplying internal power to appliances such as electric showers, cooker and induction hobs, 6mm twin and eath cable is flat for easier installation into plaster. So theres probably only about 2-4mm distance between these. Works out when the temperature of cooking is too high and turns off the source of ignition, effectively preventing kitchen fires before they start. We have the hob on top of two single ovens. Bob Rathbone Screwfix Select. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Only the sealing strip can be used. 6a = 24. High Dielectric Strength. electric oven hob; Page 2 of 2 < Prev 1 2. This stainless steel hob is compact and lightweight, and has variable independent heat control and power on the two separate cooking plates: 1500W and 750W. Buy online and collect in stores nationwide. Requires 25mm Back Box. UK call centre ready for your call 24/7. MGW Screwfix Select. Davie Active Member. MGW Screwfix Select. You are only changing the oven, so leave hob as it is. 2 x Ceramic Plates. Works at Temperatures up to 90°C. 2 x Ceramic Plates. Should an ceramic electric hob go through an rcd? the one i have if wired through the rcd trips it out when switched on. If so, spray - ideally with a straw - a small amount on that shaft and press the button repeatedly downwards. Buy Hob Appliances at Screwfix. If you disconnect or alter a gas pipe then it comes. seneca Screwfix Select. 6mm twin and earth contains brown and blue conductor cores with a bare earth which are protected by a durable PVC sheath. A tiny bead of clear sili, then wiped with a water and washing up liquid dipped finger or sponge will seal this. British General 900 Series 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket White (56392) (39) compare. 35Kw (30. White PVC Sheathed Cable. Basically a school cookery room requires 10 x electric hobs rated at 7kW each and 10 x electric ovens rated at 3 kW each . 3/5. Low price guarantee at BestBuy. Some hob manufacturers differ from these dimensions. Please do not return to store. Simple to clean. If not, then just relieve the underside of the worktop by 10mm to allow the clips to fit. Job I was called to today. Hi, I would like to replace an existing electric oven & gas hob with a new electric oven & electric hob. 590 mm. Hob. 99 Inc Vat. W x H x D: 260 x 90 x 7mm. Ceramic Hobs and Electric Ovens Installation. Should the product require repair please contact our repair service to arrange collection and repair. 1. Crabtree Capital 20A 1-Gang DP Hob Switch White (7483J) compare. Saving energy at home. kitfit1 Screwfix Select. If i had the 400v model it would be taking 2 separate live supplies, one to each terminal - seems simple. 2 x Plate Sizes. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. READ NEXT: Best gas hobs. £72. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. Most CERAMIC hobs are rated above 3kW and also require a 32A radial circuit. portlanders likes this. 2 x Plate Sizes. Also the RCD will save you if the hob has a serious electrical fault. ElecCEng, May 29,. 6 x 49. It will most likely have a 45A switch on it. the gas connection to the free standing cooker is by means of a flexible rubber pipe with bayonet fitting. Electric hob question - Help : o. I need to replace a gas hob with an electric hob and there is already an electric oven there. 9Kw/32amp and hob is at 11. Hi all, I've just tried wiring an indesit IB65B60 induction hob. Question is cable supplied with hob is 1. I hope this the right thread. Some of the hobs are pretty pants for sitting flat on the worktop. (27) £. Ozwald Cobblepot Member. Having an existing gas hob and electric oven (under counter) replaced. 29 Inc Vat. I decide to install and induction Hob and a 13 AMP electric oven, can the Induction Hob use the cooker circuit and the Oven the Kitchen? Or will I have to get a new circuit installed?. 5kW for the oven and say 6. Our current gas oven depth is 523mm & the depth of the electric oven is 560mm. Screwfix Community Forum. The induction hob will require max of 6kw/240v = 24 amp. 30 day money back guarantee. Bob C New Member. P=Power, V=Volts, and I = amps P = V x I P/V = I 8800/240 = 36. British General 900 Series 10A 1-Gang 3-Pole Fan Isolator Switch White (69862) (42) compare. Hob. The NAPIT electrician said that he needs a Installation Certificate from previous electrian before he can sort out the cooker. (24) From £249. €91. 3kW each which makes a total of 11. Large Capacity Easy to Wire Terminals. #8. com. I already have an electric oven and gas hob fitted. Screwfix customers rate this product 4. furious_customer, Oct 2. Screwfix Select. Apple Pay accepted in store. Total 40 amp. It shows 2 live terminals. 49Inc Vat. 5mm, does this mean I use a 2. £210. Will have a single electric oven and a gas hob. Plug In and Go. 5 flex wil take 18amps, from the ccu you should run 6mm to a cooker connection plate then use 6mm from here to the hob, although they supply it on some and for the cooker, what size is it the max for a fcu is 3120wattsI am going to fit my Baumatic 636. Repair Service Contact. Add to basket. The cooker switch is on the opposite wall to the hob so I couldn’t wire it there even if I wanted to. at low end you may get bent steel supports where as at the top end everything is heavy duty metal inc cast iron supports, solid knobs etc. I intend to replace the single cooker by separate hob and grill/oven units with a total power consumption intended to be no more than the existing cooker. The hob will need to sit into some form of worktop. It's a heavy base wok so distributes heat evenly unlike a thin carbon steel wok. Some hobs come with cable, some don’t. Jazzmonkey New Member. At present the oven is hard wired into a connection plate at the back of the oven. The process you describe above is more like how a microwave oven works. I've cabled up to a CCU in 6 mm cable for an electric hob. There is a switch on wall by oven. you want to install much the. You need to have a look at every joint in the cable run. Plug In and Go. Home Forums > Screwfix Community Forum > Electricians' Talk > New electric hob. I replaced my electric hob with a gas one today. Screwfix customers rate this product 4. (100) £. Hob Type: Ceramic hob. com it seems the vast majority of the cheaper single ovens only take 13amps, some even come with a 13 amp socket. The connection units will be fine behind. My first question is: is there any issue with having the hob on the same circuit as the kitchen sockets? It also says 380 to 415V between L1 and L2. ★★★★★ Read 9 reviews. Safety lock feature ensures controls are not operated by accident. It doesn't trip every time I switch it on. 2A) Applying diversity gives 100% of the first 10A plus 30% of the remaining 35. Currently in my kitchen we have a range cooker with an electric oven and a gas hob. rogerk101 Screwfix Select. I would prefer to have oven and hob on cooker circuit, then separate 20a circuit for microwave, which could also accommodate extractor hood too. That way you are not only testing it for functionality (like it heats up) but also the RCD will trip idf there is an earth leakage fault. Instructions say hob must be connected to a fused spur outlet with 3A fuse and oven must be connected to a fused spur outlet with 13A fuse (using 1mm cable). Looking at gas hobs that are 75 x 51 cm the holes required are. Home Forums > Screwfix Community Forum > Electricians' Talk > New Electric hob. #3. Stainless steel finish. Repair Service Action. Dan dan the man Active Member. 85 kg. . Hisense BI64211PB Built-in Single Multifunction pyrolytic Oven - Black. com. I will investigate same sized electric hobs, hopefully, about 70 quid and 40 pound take out and fit. Accommodates Movement of ±7. Total Product Weight. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. In the main size of cable is dictated by the size of the protection device, so we have 32, 40, 45 amp, but in the main we use 32 amp, as ovens really do not want a higher valve device when only designed for 16 amp, the cable manufactures do charts looking at the chart it seems 4 mm would do, but I would likely. One other thing is that the hob as well as other appliances connect to a 80amp mcb as we had the kitchen redone a few years ago. 7kW and the ovens 2. Order : 45a switch > dual appliance outlet > outlet 1) oven, outlet 2) 13a. its been a long time since i did 3 phase calculations so need to do some research again. 35 Kw. 6. Nomad24 New Member. sinewave, Oct 4, 2010. 7Kw so by my calculation that means the maximum current in the circuit = 10700/230 = 46. 60 days free credit available. 29 Inc Vat. Hello! We are hoping to have one side of our kitchen replaced, which will involve installing a new oven and hob unit. UK call centre ready for your call. No, it's not the same. I know I need to put an unswitched cooker outlet plate at. Total Product Weight. I too am wanting to do this. 00 Save £60. Ind spark Screwfix Select. We’re replacing our gas oven with an electric oven but keeping the gas hob. 00 View product. Screwed Faceplate. Zanussi ZHRN640K Ceramic Hob Black - 59cm. Power level 3. I'm currently changing my hob for a new one. 2kW more. Yes, as pointed out above. Requires 47mm Back Box. 2 KW (max. 5mm H05 flex for oven to outlet plate as specified in manufacture manual says the max wattage for this size cable is 3860w. Repair Service Action. Why not see if you can source an offcut of oak top and rebate the edges of it so it sits in neatly and mount the hob in that. Hi have recently purchased a neff induction hob,set up so far is 6mm cable running from 32amp mcb to 45amp isolator to 45amp connection terminal. Products reviewed by the trade and home improvers. What there is though is manufacturers fitting instructions, which should include the minimum distance from combustible material. )I'm looking to replace my electric hob and have seen one which I like which is the correct size to fit into my work top with the above power rating. £ 6. Typically used for supplying internal power to appliances such as electric showers, cooker and induction hobs, 6mm twin and eath cable is flat for easier installation into plaster. Screwfix Community Forum. Raised Square Profile. The switch will act as an isolation switch for both. thomased New Member. The sensor touch panel with an LED screen is easy to. I already have one on the kitchen wall which feeds my fan oven. The gas hob is to be removed and replaced with an electric induction hob, plus electric oven (oven rated at 16A). Electric and gas options make classic choices, while induction is. 3000w for 13A input. Thread by: Aimee88 , Feb 4, 2022 , 6 replies, in forum: Electricians' Talk Showing results 1 to 1 of 1Hendo New Member. Hi Seneca thanks for your swift reply, The Hob is 6. 5kW. Hi there. ★★★★★ ★★★★★ ( 3 ) Product code: 10534. You simply use a standard cooker circuit. 3 x Burner Sizes. Page 2 of 2 < Prev 1 2. 4 Cooking Functions. 5MM2. terrymac, Aug 5, 2023. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. com. ProDave New Member. Product Width. We have 6mm T&E from the CU to a hob isolator switch on the kitchen wall. Neither the hob or the oven should be more than 2 Mts from the control. 1A, min fuse protection rating 30A. He said he could help me out and complete the cooker line. The technical data states, conductors (number & size)3 x 2. Discussion in 'Electricians' Talk' started by jasondo23, Dec 6, 2009. 5Kw (14. The cooker is rated at 10. Most sockets feeding things like dishwashers and washing machines are mounted inside an adjacent cupboad. Now obviously this is not good and ive recommended a different layout of the kitchen and to try get the hob above some cupboards where. Start at the MCB, then look at the isolation switch, the connection to the hob and any other strange junction that the LL or his skilled assistants may have introduced. The work top is 600mm. Fires, Stoves & Electric Heating Heaters Oil Filled Radiators Underfloor Heating Electric Radiators Stoves Fireplaces Ventilation Extractor Fans Fans Air Conditioning Ducting. This Zanussi four variable zone ceramic glass hob, is not only stylish but easy to clean with residual heat indicators, meaning it's clear when it's safe to. The instruction say "Provide an Omnipolar cut off switch with a minimum contact opening of 3mm (except for plug connections if the user has access to it). Would it be possible to install it on our existing power setup for the oven?recently wired a cooker supply expecting there to be a gas hob and oven . Hi, Cheers for the quick response. Buy any 10+ Save 10% - View Offer. Page 2 of 2 < Prev 1 2. There needs to be a gap of at least 65cm between your hob and the cooker hood or ceiling. Touch-operated ceramic hob ideal for smaller cooking areas. Shop our range of hobs from Culina Appliances online today with free delivery, or click and collect from your nearest Toolstation branch. 5mm cable, supplied from a 45A cooker switch, which is supplied via 6mm cable, protected by a 40A MCB in the CU. 4. 4 x Plates. Dimensions: (H)6cm x (W)60cm x (D)53cm. A really interesting question and you are correct there is no minimum distance specified in any regulations, regarding electric hobs. . 2 x Plate Sizes. I believe the MCB rating to be 100A, but have attached a picture below for reference. 590 mm. The old units are both wired into a CCU, hob - 6mm cable, oven 2. We are replacing our gas hob. I lifted the old hob to see where the wire goes. British General Nexus Metal 13A 2-Gang DP Switched Plug Socket Antique Brass with Black Inserts (46623) (36) compare. 2 x Ceramic Plates. , Mar 15, 2018. Order online at Screwfix. The existing hob is connected to its own plug socket. It is a new hob , New World ES60 016580 but an old model . Divide the rating in watts by 230 (volts) to get the current draw figure. Should the product require repair please contact our repair service to arrange collection and repair. 276. So I changed the single socket into a double to get rid of the extension lead which was a fire hazard to begin with. 5A, then add them 10+11. any help on this would be greatly. Requires 25mm Back Box. Ah no. com it seems the vast majority of the cheaper single ovens only take 13amps, some even come with a 13 amp socket. Product information. Agreed UP, 10mm for a standard domestic cooker circuit is a total waste of money (and copper!) seneca, Feb 28, 2017. -exterior cable diameter should be at least 8. Is that correct?. 2. Screwfix customers rate this product 4. Sign in / Register. As you said no chance of. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. Hi there. 9Kw/32amp and hob is at 11. Apple Pay accepted in store. britishblue New Member. 5mm t&e cable from connector box to the hob, the distance between the two is about 500mmScrewfix Community Forum. However, the oven will still not fit because of a pipe coming down from the hob itself. com. 1 2. 56A) = 20. and you may find your hob requires even moreFront-mounted touch controls. Home Forums > Screwfix Community Forum > Electricians' Talk > Electric Oven and Electric Hob Discussion in ' Electricians' Talk ' started by RedRick , Nov 8, 2004 . Page 1 of 1. Features 4 functions including grilling and plate warming. 7kW hob. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. British General 900 Series 13A Switched Fused Spur & Flex Outlet White (86116) (63) compare. Child Safety Lock Mechanism. 6KW ( Hotpoint CRM 641 D X Electric Hob) For the cooker he has used 10mm 2 twin and earth coming from the consumer unit (2metres away) on its own mcb to a 45A cooker switch then down to a Cooker control. sparko69 Screwfix Select. Hi everyone. The oven is rated at 16 amp. UK call centre ready for your call 24/7. Bazza Screwfix Select. Buy Kitchen Appliances at Screwfix. Choose options. You don’t actually need a wide bead to seal, although you can, just a tiny bit of sili in the mm or so gap. The question is this. Helps to prevent mould and mildew. If the oven is designed to be plugged in via a 13A socket then it will be supplied with a factory fitted flex and moulded 3 pin plug. 99Inc Vat. FREE next day delivery available, free collection in 1 minute. Timer. Hobs however, usualy require a dedicated 4/6mm 32A+ supply. Offer - 20% off this when you spend £1500+ on kitchen worktops, cabinets and doors. Can't see from the spec but hob may be current limited. From £780. £7.